G5
/ GPD515 |
| |
 |
|
V/Hz, Open or Closed Loop Vector Control |
| |
|
Constant Torque Drive with Keypad as Standard |
| |
|
208-240, 460 & 600VAC upto 500HP |
| |
|
Mean Time Between Failure (MTBF): Exceeds 28 years |
| |
|
Ideal for thousands of applications – simple
to complex |
| |
|
Optional CASE application specific software (like Electronic
Lineshaft, Motion Control, etc.) flashed to on-board ROM
adds functionality to drive |
| |
|
|
|
| |
|
|
P5 /
GPD506 |
| |
 |
|
Variable Torque Drive in V/Hz Control |
| |
|
600VAC upto 200HP |
| |
|
208-240 & 460VAC models available |
| |
|
Ideal for Centrifugal Fans / Pumps - with Built-in PID
control, Energy Saving Control |
| |
|
Standard features includes Keypad & ModBus
RTU communication |
| |
|
Other integrally mounted options available |
| |
|
|
|
| |
|
|
F7 (NEW) |
| |
|
|
V/Hz,
Open or Closed Loop Vector Control |
| |
|
Constant & Variable Torque Drive with 5 line 16
character Keypad as Standard |
| |
|
208-240 & 460VAC upto 500HP |
| |
|
Mean Time Between Failure (MTBF): Exceeds 28 years |
| |
|
Industrial workhorse for every conventional application
…. And even some unconventional ones |
| |
|
Standard LCD Operator: 5 line x 16 characters –
for better monitoring & programming ease |
| |
|
|
|
| |
|
|
V7 /
GPD315&V74X |
| |
 |
|
V/Hz or Open Loop Vector Control |
| |
|
Constant Torque Drive |
| |
|
208-240 & 460VAC upto 10 / 15HP, NEMA1 |
| |
|
NEMA4X/12 enclosure available for dusty & wet environment |
| |
|
Mean Time Between Failure (MTBF): Exceeds 28 years |
| |
|
PID function with loss of feedback for process control
without additional hardware |
| |
|
Built-in Dynamic Braking transistor for low cost braking
with optional resistor |
| |
|
ModBus RTU communication as standard, other network
communication available as option |
| |
|
|
|
| |
|
|
J7 /
GPD305 |
| |
 |
|
V/Hz control |
| |
|
Constant Torque Drive |
| |
|
208-240 & 460VAC upto 5HP |
| |
|
Mean Time Between Failure (MTBF): Exceeds 28 years |
| |
|
Full range automatic torque boost function can deliver
outstanding starting torque |
| |
|
Keypad includes analog speed potentiometer |
| |
|
Ideal choice for most general applications requiring
excellent performance, low cost, and small size |
| |
|
Possible to mount on DIN rail |
| |
|
|
|
| |
|
|
P7 (NEW) |
| |
 |
|
V/Hz control |
| |
|
Variable Torque Drive for Industrial Centrifugal Fan
/ Pump |
| |
|
208-240 & 460VAC upto 500HP |
| |
|
Standard LCD Operator: 5 line x 16 characters –
for better monitoring & programming ease |
| |
|
Removable control circuit terminals and cooling fan |
| |
|
Auto-tuning function |
| |
|
Built-in bus choke above 30HP |
| |
|
Available with Bypass Package in a panel |
| |
|
|
|
| |
|
|
E7 |
| |
 |
|
V/Hz control |
| |
|
Variable Torque Drive for HVAC Fans and Pumps |
| |
|
208-240 & 460VAC upto 500HP |
| |
|
Embedded communications for building automation protocols
– Johnson Controls Metasys N2, Siemens APOGEE FLN,
as well as Modbus. Optional LonWorks Interface card available. |
| |
|
Available with Bypass Package in a panel upto 250HP
with Drive/Bypass & Hand/Off/Auto features and more |
| |
|
|
|
| |
|
|
G7 |
| |
 |
|
World’s first 3-level inverter |
| |
|
3-level architecture solves insulation and bearing failures
(460v class) |
| |
|
Increased speed / torque response for servo-like motor
control |
| |
|
V/Hz, Open or Closed Loop Vector Control |
| |
|
Constant Torque Drive with 5 line 16 character Keypad
as Standard |
| |
|
240 & 460VAC upto 500HP |
| |
|
New open loop control method resulting in true torque
control without an encoder |
| |
|
Full torque limiting capability with all 4 operation
quadrants individually set |
| |
|
Increased I/Os – 12 digital inputs, 6 digital
outputs |
| |
|
DriveWorksEZ PC graphical drive programming tool for
application solutions |
| |
|
|
|
| |
OPTIONS: |
| |
|
 |
Interface boards for wide
range of control, monitoring & network communication
capabilities |
 |
Dynamic Braking |
 |
Drive Wizard Software: Enables
upload, download and monitoring of parameters (trending,
graphing) from computer |
 |
CASE Software can add functionality
to the drive by reconfiguring drive defaults, establishing
presets for OEM equipment and by eliminating peripheral
controls and PLCs |
| |
|
| |
For
more information, please contact: |
| |
Canadian Drives Inc. at
(905) 660-2766 |
| |
E-mail: sales@canadiandrives.com |
| |
visit YASKAWA |